Real buildings.
Real numbers.

Every project here has documented results — not estimates. Office, healthcare, education, multifamily, industrial. Across Dallas–Fort Worth.

BAS Installation185,000 SF
34% energy reduction
Class A Office

Uptown Office Tower

Dallas, TX

Full BAS installation across 14 floors. Replaced legacy pneumatic controls with modern DDC on Distech/Niagara platform, reducing HVAC energy by 34% in year one.

Retro-Commissioning240,000 SF
$180K annual savings
Multi-tenant Office

Richardson Tech Campus

Richardson, TX

Retro-commissioning on a 12-year-old Siemens system. Found 22 critical faults, corrected 60+ setpoints. Documented $180K in annual savings.

BAS Installation320 Units
320 units on one platform
Multifamily Residential

Frisco Luxury Residential

Frisco, TX

New BAS installation for 320-unit luxury complex. Central plant controls, unit ventilation, and common area systems on a single Niagara supervisory platform.

Monitoring98,000 SF
$22K saved in Q1
Light Industrial

Irving Distribution Center

Irving, TX

24/7 monitoring and operations on existing JCI Metasys installation. Fault detection identified a failed economizer damper saving $22K in one quarter.

Retro-Commissioning42,000 SF
Pressure compliance restored
Medical Office

Plano Medical Office

Plano, TX

Retro-commissioning on Trane Tracer system. Corrected sequencing issues running AHUs in simultaneous heating/cooling for 3 years. Pressure relationships brought into compliance.

BAS Installation135,000 SF
New construction, on-time Cx
Industrial / Warehouse

Fort Worth Logistics Hub

Fort Worth, TX

Full BAS design and installation for new-construction logistics facility. Dock door integration, lighting control, and compressed air monitoring on a unified platform.

Commissioning68,000 SF
LEED EAc1 achieved
K–12 Education

Allen ISD Administration

Allen, TX

LEED Enhanced Commissioning for new administration building. EAc1 documentation, functional performance testing, and post-occupancy verification.

System Integration310,000 SF
3 systems → 1 platform
Mixed-Use Development

Las Colinas Mixed-Use

Irving, TX

Multi-system integration project: merged three separate BAS installations (JCI, Siemens, Trane) onto a single Niagara N4 supervisory platform for unified operations.

BAS Installation180,000 SF
99.98% uptime since commissioning
Senior Living / Healthcare

McKinney Senior Living

McKinney, TX

New BAS installation with infection control sequencing, 24/7 uptime requirements, and emergency generator monitoring. Honeywell EBI platform with Niagara integration layer.

Richardson Tech Campus

Richardson, TX
·Completed Q3 2023Retro-Commissioning

A 240,000 SF multi-tenant office campus had a Siemens BAS installed in 2011 that had never been formally commissioned. Tenants complained constantly about comfort. Utility bills had increased 18% over three years. The property manager assumed the system needed full replacement — a $900K capital expense.

We started with a full system audit — pulling 90 days of trend data, reviewing all sequences against original design documents, and walking every mechanical room. We found 22 critical faults: a cooling valve stuck at 70% for over a year, AHUs running simultaneous heating and cooling on 6 units, and occupancy schedules still set to construction defaults. No new hardware was needed. We corrected sequences, calibrated 34 sensors, updated all schedules, and enrolled the building in Oncor's demand response program.

  • 34% reduction in HVAC energy consumption
  • $180,000 in documented annual savings
  • Zero tenant comfort complaints in 6 months post-commissioning
  • 14-month ROI on the full commissioning engagement
  • Property value increased by estimated $2.1M (at prevailing cap rates)
  • $900K capital replacement project avoided

We were ready to write a check for a full system replacement. Perry Controls found the problems, fixed them in 6 weeks, and saved us more in year one than we were going to spend on new equipment. I wish we had called them three years ago.

Property Manager, Richardson Tech Campus

Las Colinas Mixed-Use

Irving, TX
·Completed Q1 2024System Integration

A 310,000 SF mixed-use development had grown over 10 years through three separate construction phases, each with a different BAS: Johnson Controls Metasys on floors 1–6, Siemens Desigo on floors 7–14, and a Trane Tracer system in the retail podium. Three separate operator workstations. Three separate alarm systems. No unified view of the building.

We deployed a Tridium Niagara N4 supervisory layer as the integration hub. BACnet drivers connected to Metasys and Siemens; Modbus TCP bridging brought in Trane data. All three systems now surface to a single unified operator workstation with a common alarm model, shared trend database, and occupancy-based logic that coordinates HVAC across all three platforms simultaneously.

  • Three BAS platforms unified under single Niagara N4 interface
  • Operations staff reduced from 3 workstations to 1
  • Cross-system demand response coordination enabled
  • 17% reduction in energy use from unified scheduling logic
  • Emergency response time reduced from 22 minutes to under 4 minutes

We had operators running between three screens to manage one building. Now it is one screen. The difference in response time alone made this project worth it — and the energy savings were a bonus we did not expect.

Director of Facilities, Las Colinas Mixed-Use

Have a project in mind?

Tell us about your building and what you are trying to accomplish. We will be straight with you about whether we can help and what it will cost.

Schedule Audit